M&S
ITA
ENG
ESP ESP
POR
RUS
 


Mills & Crushers

Screening Machines

Mixer, Granulators and Colour Machines

Transport System

Dryers

Iron Removal & Metal Detectors

Weighing System

Extraction & Dosing

Control Instruments

Spare Parts & Regenerations

 

 

  RADIANT MODULES
Pdf

RADIANT MODULES

The problem relating to the use of particularly moist materials are frequently encountered in milling systems either in the ceramics of bricks sector. Excessive moisture can lead to the formation of encrustations, condensation or the like that create difficulties in the structure of the machine. Thanks to the MS Radiant Modules of the UNIRAD and MULTIRAD types, these problems have been definitively solved.
The MS Radiant Modules of the UNIRAD and MULTIRAD types are composed of a radiant tube, to be installed on the ceiling, that reaches its operating temperature thanks to the provision of one or several burners. These Modules are controlled by an electronic metering and adjusting system. The modular construction of these radiant systems make them particularly practical and versatile in the event of extensions or repositioing, without determining a reduction of their performance level.
The UNIRAD and MULTIRAD modules operate on a radiation basis. By installing them above a certain point of the machine, they will heat that point only: thus eliminating any heat loss to the surrounding environment.
The burner are fuelled by methane gas or LPG.
Their working life is unlimited and they are maintenaince-free

IR SERIES

  • Single-Pipe, Single-Burner radiant modules
  • Up to 20kW
  • 11 - 12 - 13 mt lengths
Description
IR11
IR12
IR13
Thermal Capacity kW
16
18
20
Thermal Power kW
14,2
16,02
17,8
Consumption methane gas Nmc/h
1,61
1,81
2,01
Consumption LPG Nmc/h
0,63
0,70
0,78
Supply pressure methane gas mbar
20 - 50
Requested gas supply LPG mbar
30 - 50
Installed electric power kW
0,05
0,05
0,05
Radiant surface mq
3,59
3,65
7,3,95
Weight kg
78
82
92
Overall dimensions LxWxH mt
11,9x0,7x0,6
12,9x0,7x0,6
13,9x0,7x0x6

UR SERIES

  • Double-Pipe, Single-Burner radiant modules
  • Up to 40kW
  • 6 - 9 - 12 mt lengths
Description
UR6
UR9
UR12
Thermal Capacity kW
16 - 20
24 - 30
34 - 40
Thermal Power kW
14,2 - 17,8
21,3 - 27
30,6 - 36
Consumption methane gas Nmc/h
1,6 - 2,01
2,41 - 3,02
3,42 - 4,02
Consumption LPG Nmc/h
0,63 - 0,78
0,94 - 1,17
1,33 - 1,56
Supply pressure methane gas mbar
20 - 50
Requested gas supply LPG mbar
30 - 50
Installed electric power kW
0,05
0,05
0,18
Radiant surface mq
3,71
5,51
7,30
Weight kg
87
124
164
Overall dimensions LxWxH mt
6,6x0,7x0,6
9,6x0,7x0,6
12,6x0,7x0x6

BR SERIES

  • Double-Pipe, Double-Burner radiant modules
  • Up to 50kW
  • 12 - 15 - 18 mt lengths
Description
BR12
BR15
BR18
Thermal Capacity kW
35
44
50
Thermal Power kW
31,5
39,6
45
Consumption methane gas Nmc/h
3,52
4,42
5,03
Consumption LPG Nmc/h
1,37
1,17
1,95
Supply pressure methane gas mbar
20 - 50
Requested gas supply LPG mbar
30 - 50
Installed electric power kW
0,18
0,18
0,18
Radiant surface mq
7,49
9,28
11,08
Weight kg
176
213
246
Overall dimensions LxWxH mt
13,2x0,7x0,6
16,2x0,7x0,6
19,2x0,7x0x6

 

The data shown is indicative and may vary without notice

 


Via G.M. Dallari, 2 - 41049 Sassuolo (MO) - Italy
Tel. +39-0536-801207 Fax: +39-0536-807248
Email: sales@ms-plants.it